I technical specification – Epson XK3190-H2B User Manual
Page 3

I Technical Specification
1. Model
XK3190-H2B
2. Accuracy
Meets the regulations of OIML, R76, JJG-555
and national standard of the electronic crane
scale. Accuracy - Class Ⅲ
Division
From 0.01 to 50, 12 options in total. Verifying
division will be set automatically each time when
powered on. Usually, the division is supposed
not to be modified.
Units of Measure
4 options: t, kg, g and mg
3. Analogue
Conversion Principle
24 bit ∑-△ mode, A/D converter
Input Signal Range
-2mV~+18mV
Max Net Input Signal
20mV
Conversion Rate
6.25 times per second
A/D Conversion Resolution
500,000
Non-linearity <0.01%F.S
F.S. Temperature Coefficient
<6PPM/℃
Calibration
Full
digital
calibration
(FDC)
Load Cell Excitation DC
5V
Load Cell Drive Capacity
up to 4 load cells at 350Ω
Connecting Method of Load Cell
4 leads
Displaying Cycle
160ms
4. Clock
Displaying Y/M/D, H/M/S and leap year/month
Accuracy
±
5s/24h, free from influence of powering off
5. Keypad
Digital Keys
0~9, ·, -
Function Keys
24 (12 overlapped with digital keys)
Key Material Sealed elastomer
6. Scoreboard Interface
Serial output mode
Transmission Mode
20mA current loop
Data Type
11 bits
Baud Rate
600
Transmission Distance
≤
2000m
7. Serial Communication Interface
Transmission Mode
RS232C/RS422 (Optional)
Baud Rate
600, 1200, 2400, 4800, 9600
Transmitted data format
10 bit:1 start bit, 8 data bits (ASCⅡ Code), 1
stop bit
Transmission Distance
RS232:≤30m
RS422:≤1200m
8. Printer Port
Standard parallel output port
9.
Data
Storage
11 categories of weight records, net/gross