beautypg.com

Trouble-shooting, Spare parts – Florabest FRP 350 C2 User Manual

Page 48

background image

48

GB

Trouble-shooting

Problem

Possible cause(s)

To correct the fault

Pump does not

start

No power supply

Check socket, cable lead and plug, if

necessary have a repair carried out

by an electrician

Float switch ( 6) does not

operate

Check the position of the float switch

Water level inadequate when

starting

Submerge the pump deeper

Thermal protection switch has

tripped

Wait until motor cools down and

switches on again. Unplug appliance

and clean suction foot/impeller wheel.

Pump is running,

but not pumping

water

Suction foot ( 8) /

filter ( 7) blocked

Clean suction foot / filter

Pressure lead closed

Open the distributor shut-off tap (

18), other tap or jet, etc.

Pumping capacity affected by

extreme dirt or abrasive solids

mixed with the water

Withdraw the power plug and clean

the pump, if necessary replacing worn

parts.

Pump does not

switch off

Float switch ( 6) cannot sink Check position of the float switch

Amount pumped

is inadequate

Suction foot ( 8) /

filter ( 7) blocked

Clean suction foot / filter

Pumping capacity affected by

extreme dirt or abrasive solids

mixed with the water

Withdraw the power plug and clean

the pump, if necessary replacing worn

parts (see “Cleaning, maintenance

and storage”).

If necessary, operated the pump with-

out the distribution piece.

Pump switches off

after only running

a short time

Motor protection switches off

the pump because of exces-

sively dirty water.

Withdraw the power plug and clean

it.

Water temperature is too high,

Motor protection switches the

appliance off.

Maximum permitted water temperature

of 35°C must be observed!

Spare parts

When you wish to purchase spare parts, please contact our Service Center.