Installation – Enviro 50-1095 User Manual
Page 5
5
Installation
D
ECIDING
W
HERE
TO
L
OCATE
YOUR
P
ELLET
A
PPLIANCE
:
1. Check clearances to combustibles.
2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may
be obtained from a ventilated crawlspace.
3. Do not install the stove in a bedroom.
4. You can vent the stove through an exterior wall behind the unit or connect it to an existing masonry
or metal chimney (must be lined if the chimney is over 6” (15 cm) diameter, or over 28 inches² (180
cm²) cross sectional area). An interior vent can be used with approved pipe passing through the
ceiling and roof.
5. Locate the stove in a large and open room that is centrally located in the house. This will optimize
heat circulation.
6. The power cord is 8 feet (2.43 m) long and may require a grounded extension cord to reach the
nearest electrical outlet.
R
EMOVING
P
ELLET
S
TOVE
F
ROM
P
ALLET
:
1. Remove the right and left hand cabinet sides by
loosening the three (3) T-20 Torx screws on the
back of the each panel.
2. Remove the screw located on the front of the
cabinet side, below the louvers and loosen the
screw behind the ash door.
3. Using a
5
/
16
” socket of flat head screwdriver,
remove the three (3) wood screws that are holding
the bottom of the stove to the pallet. There is one
(1) screw behind each side panel and one (1) at the
back behind the back grill.
4. Close the side panels.
5. Install the four (4) leveling legs into the nuts in the
base.
Figure 1: Screws to take out to remove stove from
pallet.