beautypg.com

Pilot flame characteristics – Empire Comfort Systems VFDR18LB User Manual

Page 17

background image

Page 17

21565-3-0906

Figure 18 shows a correct pilot flame pattern. The correct flame

will be blue and will extend beyond the thermocouple. The flame

will surround the thermocouple just below the tip. A slight yellow

flame may occur where the pilot flame and main burner flame meet.

Figure 19 shows an incorrect pilot flame pattern. The incorrect

pilot flame is not touching the thermocouple. This will cause the

thermocouple to cool. When the thermocouple cools, the heater

will shut down.
VFDR (Series) PILOT

Correct Pilot Flame Pattern

Figure 18

Incorrect Pilot Flame Pattern

Figure 19

If pilot flame pattern is incorrect, as shown in Figure 19

• See Troubleshooting, page 19.

Cleaning and Maintenance/Pilot

Oxygen Depletion Sensor Pilot (Figure 20)

When the pilot has a large yellow tip flame, clean the Oxygen

Depletion Sensor as follows:
1. Clean the ODS pilot by loosening nut B from the pilot tubing.

When this procedure is required, grasp nut A with an open end

wrench.

2. Blow air pressure through the holes indicated by the arrows.

This will blow out foreign materials such as dust, lint and spider

webs. Tighten nut B also by grasping nut A.

Figure 20

PILOT FLAME CHARACTERISTICS