beautypg.com

Switching the power function on and off – Electrolux 67160KFN 67160 KF-N User Manual

Page 14

background image

Operating the appliance

14

Switching the power function on and off

The power function makes more power available to the induction cooking zones,

e.g. to bring a large quantity of water to the boil quickly.

The power function remains activated for differing periods of time:

3

If the power function has ended, the cooking zones automatically switch back to

the heat setting set previously.
Power Management

The cooking zones of the cooking surface

have a maximum power available to them.

Two cooking zones make up a pair (see fig-

ure).

So that the Power function can always be

carried out, Power Management may re-

duce the power of the other cooking zone

in the pair
Example: heat setting 9 is selected on a

cooking zone. The Power function is

switched on for the cooking zone paired up

with it. The Power function is performed,

but heat setting 9 on one cooking zone and Power function on the other cook-

ing zone of a pair exceeds the maximum output for both. Therefore Power Man-

agement reduces the first cooking zone that was switched on from 9 to 7, for

example, and the display for this cooking zone alternates between 9 and 7 and

then remains on the current maximum of 7. (Whether the display alternates be-

tween 9 and 7 or 9 and 6 or other values, depends on the appliance type and the

size of the cooking zone.)

Control panel

Display

Switch on

Touch

Switch off

Touch

Touch

Cooking zone

diameter [mm]

Power time [min]

210

8

145

2