Special safety instructions, Intended use, Before first use – Elta 9050N5 User Manual

Page 6: Mounting, Opera tion

background image

9

10

GB

GB

GB

GB

concerning use of the appliance by a person responsible for their safety

.

Children should be supervised to ensure that they do not play with the

appliance.

SPECIAL

SAFETY

INSTRUCTIONS

The protection basket must be closed properly when operating the

device.

Do not put your fingers or any other objects in the protection basket

during operation. Do not remove the protection basket during

operation.

Infants, children and elderly persons should not be exposed to the cold

air stream over a long period of time.

Do not operate the device in an extremely hot or moisten environment

(e.g. bathroom).

Unplug the device before cleaning or demounting it.

Do not operate the device in a horizontal position or without a base.

Keep the device away from lose objects such as plants, curtains, etc.

Do not plug the device into the socket before it is not mounted

completely

.

INTENDED USE

The device is intended for private use and fanning only

.

The device is

not intended for commercial or industrial use.

BEFORE FIRST USE

Remove all packaging material.

Clean the device as described below under

Cleaning and

Maintenance.

Dry all parts carefully before using the device.

MOUNTING

Remove the screws from both parts of the base plate and place them

crosswise on each other

.

T

o

pull out the telescope tube from the stand tube casing, simply push

the telescope tube from the bottom of the stand tube casing if the

telescope tube is retracted. Use an auxiliary object such as a blunt

wooden stick.

Place the stand tube on the base plate and tighten it with the four

screws.

Unscrew the adjusting screw cap (19) from the stand tube counter

clockwise and slide the cover (20) on the junction between the base

plate and the stand tube.

Place and screw the adjusting screw cap onto the stand tube. Pull out

the telescope tube until you have reach the desired extent, then

tighten the screw cap.

Loosen the set screw (17). Please note that the hexagon nut (18) is

mounted on the inside.

T

urn the set screw until the upper part of the

device can be placed on the telescope tube. Place the upper part of

the device on the telescope tube and tighten the set screw

.

T

urn the clamping knurled-head screw (3) at the front of the rotor shaft

(1

1) clockwise to the position “Loosen” and remove it.

T

urn the clamping ring (5) at the rear of the rotor shaft counter

clockwise and remove it from the motor casing (12). Place the rear

protection basket (7) on the motor casing and make sure that the

holes and handle line up properly

.

The round opening on the inside of

the protection basket’

s metal ring must lay on the cam of the motor

casing.

Screw the clamping ring clockwise into the screw thread so that the

rear protection basket fits tightly to the motor casing.

Slide the rotor (4) on to the rotor shaft (1

1).
The mounting on the rotor

shaft must be placed on the designated opening of the rotor

.

T

ighten the rotor by turning the clamping knurled-head screw (3) on

the rotor shaft counter clockwise to the position “TIGHTEN”.

Place the front protection basket (1) in to the basket hook (8) and

close the four holding clips (6) at the rear protection basket.

Put the front protection basket into position so that the bores on the

upper part of the protection baskets are on top of each other

.

Therefore loosen the holding clips a little bit.

Insert the screw (2) into the bore holes of the protection baskets and

secure it with the proper hexagon nut (9). Close all open holding clips

on the protection basket.

The mounting is finished and the stand ventilator is ready to operate.

OPERA

TION

Plug the power plug (23) into a suitable socket.

Select your desired fanning speed by turning the switch in the 0 / 1 / 2

/ 3 (16) position.

0 =

device is of

f.

1 =

low speed

2 =

medium speed

3 =

high speed

T

o

let the ventilator head constantly oscillated from left to right, push

the oscillation switch downwards (13).

T

o

direct the air stream on a

concentrated place, simply pull the oscillation switch upwards until the

desired position is reached.

The bend of the ventilator head can be adjusted.

T

urn of

f the

oscillation switch beforehand by pulling the switch upwards. Remove

the knurled-head screw (15) from the vertical joint (14).

T

ake the

handle (10) of the protection basket and tilt the ventilator head to the

desired position.

T

ighten the knurled-head screw

.