44 electrolux care and cleaning

• Open the pump door.

• Place a containfer close to the pump

to collect any spillage.

• When no more water comes out, unscrew

the pump cover and remove it. Always

keep a rag nearby to dry up spillage of

water when removing the cover.

• Remove any objects from the pump

impeller by rotating it.

• Screw the pump cover fully in.

• Close the pump door.

Warning!
When the appliance is in use and

depending on the programme selected

there can be hot water in the pump.
Never remove the pump cover during a

wash cycle, always wait until the

appliance has finished the cycle, and is

empty. When replacing the cover, ensure

it is securely retightened so as to stop

leaks and young children being able to

remove it.
Cleaning the water inlet filter
If your water is very hard or contains

traces of lime deposit, the water inlet

filter may become clogged.

It is therefore a good idea to clean it

from time to time.

Turn off the water tap. Unscrew the water

inlet hose. Clean the filter using a hard

bristle brush. Tighten up the inlet hose.

The dangers of freezing
If the machine is exposed to

temperatures below 0°C, certain

precautions should be taken.
• Turn off the water tap.
• Unscrew the inlet hose.

• Place the end of the inlet hose in a

bowl placed on the floor and let water

drain out.

• Screw the water inlet hose back on.

• When you intend to start the machine

up again, make sure that the room

temperature is above 0°C.

Important!
Every time you drain the water through

the emergency emptying hose you must

pour 2 litres of water into the main wash

compartment of the detergent drawer

and then run the drain programme. This

will activate the ECO VALVE device

avoiding that part of the detergent

remains unused at next washing.

126.2931.37…EWF 127112 W:- 12/07/10 16:46 Página 44