beautypg.com

Power up, Set the time and day, Adjust the temperature setpoints – Elemental Designs eStat 761 User Manual

Page 2: Select the operating mode, Program your schedule

background image

eStat 761/762

400-132-028-A 11/6/07 2/3

On the first installation, the screen displays: 0:00, MO,

and temperature (room/floor).

For Floor Heating Installations:

One of the two following messages may be displayed
when a problem occurs:

LO

: The floor temperature is below 0°C, or the

temperature sensor is defective, or not connected.
The heating indicator

is displayed and the relay is

closed (energized).

HI

: The floor temperature is above 60°C, or the

temperature sensor is defective.

n

Set the time (HOUR - MIN).

o

Set the day (DAY).

If you remove the module from its base for
more than 2 hours, the time and day will have
to be reprogrammed.

Comfort

and Economy

Setpoints

These setpoints are associated with the schedule’s programs (prog.
1 & 3 = Comfort, prog. 2 & 4 = Economy) and are preprogrammed as
follows:

eStat 761—

28°C, 20°C

eStat 762—

20°C, 18°C

To modify a setpoint:

n

Set the temperature using

and press and hold the

or

button until it is displayed on the screen.

o

Press MODE/RETURN to exit.

Vacation Setpoint

The vacation setpoint is associated to the Vacation operating mode
and is preprogrammed to 10°C. To modify this setpoint, repeat above
steps.

Floor Temperature Setpoint (eStat 762)

The floor temperature limit is preprogrammed to 28°C to avoid dam-
age to your floor.
To modify, press the adjustment button (below

) using a pointed

object, set the desired temperature using

and press MODE/

RETURN to exit.

The eStat thermostat offers three operating modes:

Automatic

Executes the schedule.

n

Press MODE to select

. The current

program number is displayed.

You can temporarily bypass the current program by
setting a specific temperature setpoint

or by

selecting one of the pre-defined setpoint buttons
(

). The new setpoint will be maintained until the

beginning of the next program.

Manual

—Maintains a constant temperature.

n

Press MODE to select

.

o

Set temperature

or select one of the pre-defined

setpoint buttons (

).

Vacation

—Maintains the Vacation setpoint during a

prolonged absence.

Press .

The schedule is used with the Automatic mode. The schedule con-
trols the heating system to automatically switch between the Comfort
and Economy temperature setpoints at the times you have pro-
grammed.
The schedule consists of 4 programs per day defined as follows:

To enter the programs’ start time

To shorten programming, you simply have to enter the start time for
each program.

n

Press PGM.

o

Press DAY to select the day (hold for 3 seconds to select all
days of the week).

Note:

It is sometimes faster to program the same schedule for the

entire week and then to modify the exception days.

p

Press PGM to select the program number (e.g. 1).

q

Press HOUR and MIN to set the start time.

r

Repeat steps 3 to 4 for remaining programs (e.g. 2, 3 and 4).

s

Press MODE/RETURN to exit.

Note:

After 60 seconds of inactivity, the thermostat will automatically

exit programming mode.

r

Power Up

4.

s

Set the Time and Day

5.

t

Adjust the Temperature Setpoints

6.

u

Select the Operating Mode

7.

v

Program Your Schedule

8.

Programs

Setpoint

Time

a

a.

The programs’ start time can be different for each day of the week.

Wake-up

Leave home

Back home

Night

400-132-028-A (CJ Electric Elements TH132 F_AF 15-min eStat 761_762) ENG.fm Page 2 Monday, June 11, 2007 4:26 PM

This manual is related to the following products: