beautypg.com

Routine cleaning and maintenance – Enviro BERN C-10629 User Manual

Page 12

background image

Routine Cleaning and Maintenance

Removal of the firebox backing.

• Open the door by lifting the handle, remove the burn pot and burn pot liner.

• Lubricate all screws with penetrating oil.

• Remove the four (4) screws that hold the side panels in place.

• With the tip of a flat screwdriver, gently lift up the side panels and remove the side panels.

• Pull the center panel out.

• Vacuum thoroughly.
Installation of firebox backing:

• Insert center panel.

• Place the side panels back into the firebox locking them into place and re-install the two (2) screws on

each side.

• Clean thoroughly.

EXHAUST VENT (annually)
This vent should be cleaned every year or after two tons of pellets. We recommend contacting your

dealer for professional cleaning. To clean the vent pipe, tap lightly on the pipe to dislodge any loose ash.

Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of the vent pipe as

possible.

BLOWER MECHANISMS (season)
Unplug the stove then open the right and left side panels to access the two blowers. Vacuum all dust

from motors. DO NOT lubricate the motors. Check gaskets and replace if needed.

POST SEASON CLEAN-UP
Once you are finished using the pellet appliance for the season, unplug the stove for added electrical

protection. It is very important that the stove be cleaned and serviced as stated above.

FIREBOX PANEL
The paint on the steel firebox panels may peel. This is due to extreme conditions applied to the paint and

is in no way covered by warranty.

DOOR GLASS REPLACEMENT
It is recommended that your dealer replace the glass if broken. The door glass is made of high temperature

PYRO CERAMIC. To replace the glass, unscrew and remove the four glass retainers. Remove the glass

and any broken pieces. High temperature fiberglass tape should be used around the glass. Replace the

glass by securing the glass retainers back to the frame ensure the glass is seated against the bottom

glass retainer screws. The use of substitute materials is prohibited use only part 50-1155.

12