beautypg.com

Operatings instructions, Technical data – Electrolux 3531 WK-M User Manual

Page 6

background image

6

Burner markings

The operating knob has a ring showing
the scale of markings.

Off.

Max. flame
and ignition position

Min. flame

Operatings instructions

15

Type of gas
Natural, G-20 - 20mbar

Category and pressures
II

2H3+

20 - 28/37 mbar

Max. nominal load Q, H

S

:

Wok burner =

3,9 kW x 1

Total=

3,9 kW

FSD
The unit features fully-secured gas taps
(thermo-fuse).

H

S

= Gross calorific value

Q =

Nominal load

Voltage=

220-240 V AC

Ignition transformer=

50 HZ - 0,6 VA

CE 048 BO- 0039

Radio-noise reduction
This unit observes the current EEC-directive
on radio noise reduction.

This gas appliance is -approved and mar-
ked in accordance with the gas appliance
Directive (90/396/CEE), the low voltage
directive (73/23/CEE) and the EMC directive
(89/336/CEE incl. the agreed directive
changes.

Technical data

The Dropinett must be connected via
an external switch with a contact
gap of min. 3 mm (the main switch
may be used)

Cable type: 0,75 mm² HO5VV-F

N L1

240 V
1N + PE