Important ! Note!

Remove the mains plug before all maintenance work.

 When the pump is often transported in the course of operation, it should be cleaned out

with clear water after every use.

 In case of stationary installation, the function of the bating switch should be checked every

3 months.

 All fibrous particles which may have built-up inside the pump housing should be removed

with a water jet.

 Every 3 months the shaft ground and as should be cleaned from mud.
 Remove deposits on the floater with clear water.

9.2

Cleaning the impeller

If excessive deposits collect in the pump case you must dismantle the bottom part of the pump
as follows:
1.

Remove the intake cage from the pump case.

2.

Clean the impeller with clear water.

Important! Do not put down or rest the pump on the impeller!
3.

Re-assemble in reverse order

10 TECHNICAL DATA

type

POWXG9418

Voltage / frequency

230V / 50Hz

Power input

900W

Delivery rate max..

13500 l/h

Delivery height max

9 m

Immersion depth max.

max. 7 m

Water temperature max.

35° C

Hose connection

5/4"

Foreign bodies up to

35 mm

Switching point high: ON

ca. 55 cm

Switching point high: OFF

ca. 5 cm

For clean/dirty water:

Dirty

Housing (plastic(P) / Stainless Steel (SS) )

SS

Water inlet (plastic / Stainless Steel (SS) )

P

Weight

6.5 kg

11 SERVICE DEPARTMENT

 Damaged switches must be replaced by our after-sales service department.
 If the connecting cable (or mains plug) is damaged, it must be replaced by a particular

connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).