8.4
Storage
I mportant! Pull the mains plug out of the socket and ventilate the appliance
and all connected pneumatic tools. Switch off the compressor and make
sure that it is secured in such a way that it cannot be started up again by
any unauthorized person.
Important! Store the compressor only in a dry location which is not
accessible to unauthorized persons. Always store upright, never tilted!
9 TECHNICAL DATA
Type
POWX1725
Rated voltage
230 V
Rated frequency
50 Hz
Rated Power
1100 W / 1,5 pk
Rotation speed
3400 min
-1
Rated Pressure
8 bar / 116PSI
Tank capacity
24 l
Air debit (capacity)
180 l/min
Weight
20 kg
10 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
77 dB(A)
Acoustic power level LwA
97 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT
CAUSE
REMEDY
The
compressor
does not start
1. No supply voltage
1. Check the supply voltage, the
power plug and the socket-outlet.
2. Insufficient supply voltage
2. Make sure that the extension
cable is not too long. Use an
extension cable with large enough
wires.
3. Outside temperature is too
low
3. Never operate with an outside
temperature of below +5°C.
4. Motor is overheated
4. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
The
compressor
starts but there is
no pressure
1. Leak in the non-return
valve
1. Replace the non-return valve
2. The seals are damaged.
2. Check the seals and have any
damaged seals replaced by a service
center