Don’ts, Use of the compressor, Voltage – Powerplus POWX1723 COMPRESSOR 1100W 12L NO OIL 1,5HP EN User Manual
Page 5: Switching on/off, Powx1723, 7 use of the compressor
POWX1723
EN
Copyright © 2014 VARO
P a g e
| 5
www.varo.com
Always maintain a safety distance of at least 2 meters between the compressor and the
work area.
Check for correspondence between the compressor plate data with the actual
specifications of the electrical system. A variation of ± 10% with respect of the rated value
is allowed.
Insert the plug of the electrical cable in a socket of suitable shape, voltage and frequency
complying with current regulations.
Use extension cables with a maximum length of 5 meters and with a cable cross-section
of not less than 1.5 mm2. Use of extension cables of different length and cross-section
and also of adapters and multiple sockets should be avoided.
Always use the handle to move the compressor.
When using compressed air, you must know and comply with the safety precautions to be
adopted for each type of application (inflation, airpowered tools, painting, washing with
water-based detergents only, clinching, etc.).
To avoid overheating of the electric motor, this compressor is designed for intermittent
duty operation as indicated on the technical dataplate (for example, S3-15 means 1.5
minutes On, 8.5 minutes OFF). In case of overheating, the thermal cutout of the motor is
released, automatically cutting off the power when the temperature is too high due to
excess current take-off. The motor restarts automatically when normal temperature
conditions are restored.
6.2
D
on’ts
Never direct the jet of air towards persons, animals or your body.
Never let the compressor come into contact with water or other liquids and never direct the
jet of liquids sprayed by tools connected to the compressor towards the compressor: as
the appliance is live, this could cause electrocution or short-circuits.
Never use the appliance with bare feet or wet hands or feet.
Never yank the power cable to disconnect the plug from the power outlet or to move the
compressor.
Never leave the appliance exposed to adverse weather conditions (rain, sun, fog, snow).
If this compressor is used outdoors, always remember to stow it after use in a covered or
closed place
Never use the compressor outdoors in rain or bad weather.
Never allow inexpert persons to use the compressor without suitable surveillance. Keep
animals at a distance from the work area.
The compressed air produced by the compressor cannot not be used for pharmaceutical,
food or medical purposes or to fill the air bottles of scuba divers.
Do not place flammable or nylon/fabric objects close to and/or on the compressor.
Do not cover the air inlets on the compressor.
Do not open or tamper with any part of the compressor. Contact an authorized Service
Center.
7 USE OF THE COMPRESSOR
7.1
Voltage
The compressor is equipped with a mains cable with shock-proof plug. Before you use the
machine, make sure that the mains voltage complies with the specifications on the rating plate.
Long supply cables, extensions, cable reels etc. cause a drop in voltage and can impede
motor start-up. In the case of low temperatures below +5°C, motor start-up is jeopardized as a
result of stiffness.
7.2
Switching ON/OFF
To switch on the equipment set the On/Off push the switch (ref. 1). Push the On/Off switch (ref.
1) again to switch off the equipment.