Operation, Assembly instructions, Work rest adjustment – Powerplus POWX1250 B ENCH GRINDER COMBI 350W EN User Manual
Page 5: Operating, Changing grinding wheels
POWX01250
EN
Copyright © 2014 VARO
P a g e
| 5
www.varo.com
The supply cable is intended for normal conditions of use. It is designed to resist normal
mechanical stresses. Do not make loops in the cable or put objects which might damage it
on top of it. Also make sure that the cable does not come into contact with any liquid or
any source of heat and that it is not used in a damp environment. Do not withdraw the plug
from the socket by pulling on the cable.
Before any maintenance operation, manipulation or any intervention on the machine (such
as assembly, disassembly, adjustment, etc), always disconnect the power supply plug and
wait until the machine has come to a standstill.
It is compulsory to wear certified gloves and protective goggles when using the device.
Never use the machine without its protective guard and “spark guards”.
Always check that the work supports are firmly fixed before using the machine.
As the wheel wears down, adjust the work support and screen slide:
1.5mm between the work support and the wheel
2mm between the slide and the wheel
When using the grinder, stand in a stable, balanced position, without stretching, and keep
children at a distance.
Never leave the machine running unsupervised. Keep the workshop clean and tidy.
Before use, make sure the grinding wheels are not damaged or cracked. If there is the
slightest doubt, replace at once (a damaged grinding wheel can fly apart at speed).
Replacement grinding wheels must be identical in characteristics and dimensions.
This machine is not suitable for grinding soft substances such as lead, magnesium or light
alloys.
7 OPERATION
7.1
Assembly instructions
Before use, the eye shields/spark arresters must be fitted to the grinder. Remove both eye
shields from packaging, position the shields over the two mounting brackets above the
grinding wheels with the flanges of the spark arrester facing away from you, fix with the screw
and washer provided. At this stage do not fully Tighten.
7.2
Work rest adjustment
Take the work rest out of the package, fix on the grinder with the knob and washer provided
as shown in dia3. The gap between the rests and the wheels should be checked before use.
Measure the gap between the grinding wheel and the rests; this should be as small as
possible not greater than 2 mm, if not, loosen the two knobs on each of the rests, set the
correct gap and fully tighten. The gap must be maintained as the wheel wears.
7.3
Operating
Make sure grinder is securely mounted; mounting holes are provided in the base of the grinder
for this purpose, but the screws are not provided. Plug in the mains supply and push the on/off
switch right to the on position. Switch off and unplug the grinder when not in use.
7.4
Changing grinding wheels
To change the grinding wheels, first unplug from mains supply then remove the eye shield
brackets, then undo and remove the three screws holding the wheel guard covers in place.
Remove the cover. Undo and remove the two wheels retaining nuts (a). You may have to hold
the wheel and give the spanner a firm tap with a soft headed hammer to release the nut, take
off the large domed washer(b), paper washer(c) and remove the wheels(d).