7.3
Checking the oil-level
§ Check the oil-level prior to each use
§ The level has to coincide with the red dot on the gauge glass.
§ If the level is below the mark, refill the oil.
7.4
Checking the safety valve
Check the operation of the safety valve prior to each use.
§ Make sure that the tank is pressure free. The pressure
gauge must indicate 0 bar.
§ Pull the ring a number of times. The pin should move
freely.
Do not use the machine if the pin in the safety valve cannot move freely. Do
not perform any adjustments to the safety valve.
7.5
Checking and cleaning the air filter
Check the air filter every 3 months.
§ Let the machine cool down.
§ Pull the air filter from the cylinder head.
§ Clean the filter with dry air. If necessary replace the filter.
§ Pull the air filter back into the cylinder head.
8
TROUBLE-SHOOTING
If the machine does not work correctly, follow the directions below to solve the problem. If you
can’t solve the problem yourself, contact your dealer.
8.1
Engine does not start
§ Check that the on/off switch is in the "ON" position.
§ Check that the power supply corresponds to the voltage on the rating plate of the
machine.
§ Check that the fuses in the meter cupboard are intact.
§ Check that no extension cords are used that do not comply with the applicable regulations.
§ Check that the work environment is not too cold.
8.2
Compressor does not supply air
§ Check that the pressure regulator is adjusted correctly.
8.3
Pressure is too high
§ Check if the hose is connected to the correct valve.
§ Re-adjust the pressure.
8.4
Thermal shutdown switch:
The electric motor is equipped with an automatic thermal overload protector. If the unit is
overheating, the motor will automatically shut down. Turn the unit off and wait 5-10 minutes
before turning the unit back to the “I”(ON) position. If the unit shuts down again, please contact
the manufacturer for assistance.