Technical data, Maintenance, Powxq8125 en – Powerplus POWXQ8125 COMPRESOR 2200W 50L LUBRICATED EN User Manual
Page 6: 5 technical data, 6 maintenance
POWXQ8125
EN
Copyright © 2010 VARO
P a g e
| 6
www.varo.com
The compressor continues to operate automatically with this work cycle until the position
of the switch of the pressure switch (or of the selector of the electric panel) figures 5a-5b-
5c-5d) is modified. To use the compressor again, wait at least 10 seconds after this has
been switched off before restarting.
In the versions with electric panel, the pressure switch must always be aligned with the I
(ON) position.
In tandem versions, the control unit provided permits use of only one of the two
compressor groups (if necessary alternatively) or of both at the same time according to
requirements. In this second case, start-up will be differentiated slightly to avoid
excessively high current take-off at start-up (timed starting).
Only the wheel-mounted compressors are fitted with a pressure reducer (in the versions
with fixed feet, it is usually installed on the use line). Air pressure can be regulated in order
to optimize use of air-powered tools operating on the knob with the valve open (pulling it
up and turning it in a clockwise direction to increase pressure and counterclockwise to
reduce this) (fig. 7). Once you have set the value required, push the knob down to lock it.
The value set can be checked on the gauge (for versions equipped with this, fig. 8).
Please check that the air consumption and the maximum working pressure of the
pneumatic tool to be used are compatible with the pressure set on the pressure regulator
and with the amount of air supplied by the compressor.
When you have finished working, stop the machine, pull out the plug and empty the
reservoir.
5 TECHNICAL DATA
Type
POWXQ8125
Rated power
3hp
Current take-off
5A
Power supply voltage
230 V/50 Hz
Air intake
270l/min
Maximum pressure
10bar
Weight
+/- 48kg
Isolation class
B
Tank capacity
50l
6 MAINTENANCE
The service life of the machine depends on maintenance quality.
PRIOR TO ANY OPERATION SET THE PRESSURE SWITCH TO THE OFF POSITION,
PULL OUT THE PLUG AND COMPLETELY DRAIN THE RESERVOIR.
Check that all screws (in particular those of the head of the unit) are tightly drawn up (fig.
9). The check must be carried out prior to the first compressor starting.
TABLE 1
– TIGHTENING OF HEAD TENSION RODS
Nm
Min torque
Nm
Max torque
Screw M6
9
11
Screw M8
22
27
Screw M10
45
55
Screw M12
76
93
Screw M14
121
148
Clean the suction filter according to the type of environment and in any case at least every
100 hours. If necessary, replace the filter (a clogged filter impairs efficiency while an
inefficient filter causes harsher wear on the compressor (figures 10a - 10b).