Electrolux EWW 167443 W User Manual
Page 22
7. Remove fluff and objects from the
pump.
8. Make sure that the impeller of the
pump can turn. If this does not occur,
contact the service centre.
9. Clean the filter under the water tap and
put it back in the pump into the special
guides.
10. Make sure that you tighten correctly the
filter to prevent leakages.
2
1
11. Close the drain pump door.
Warning!
Never remove the pump cover during a
wash cycle, always wait until the appliance
has finished the cycle, and is empty. When
refitting the pump cover, ensure it is se-
curely re-tightened so as to stop leaks and
young children being able to remove it.
CLEANING THE WATER INLET
FILTERS
If you notice that the machine is taking lon-
ger to fill, check that the filter in the water
inlet hose is not blocked.
1. Turn off the water tap.
2. Unscrew the water inlet hose.
3. Clean the filter in the hose using a hard
bristle brush.
4. Screw the hose back onto the tap.
5. Unscrew the hose from the machine.
Keep a rug nearby because some wa-
ter may flow.
6. Clean the filter in the valve with a stiff
brush or with the piece of cloth.
7. Screw the hose back to the machine
and make sure the connection is tight.
8. Turn on the water tap.
EMERGENCY EMPTYING OUT
If the appliance cannot drain the water, pro-
ceed as follows to empty out the machine:
1. pull out the plug from the power sock-
et;
2. close the water tap;
3. if necessary, wait until the water has
cooled down;
4. open the pump door;
5. place a container on the floor below the
recess of the drain pump;
22 electrolux