4.4.2) Full Scan Replace Existing Services
When 'Full Scan Replace Existing Services' option is selected, the
same as the 'Full Scan Add New Services' menu is displayed except
that the existing services in the system are deleted before the scan
starts.

Full Scan Replace Existing Services

Manual Scan Menu

4.4.3) Manual Scan
This menu allows the user to manually tune in services.This menu
will have different parameters.

Editable options are:
Channel
Sets the required UHF channel. This will automatically
fill in the frequency entry.
Frequency Overrides and set the frequency in kHZ.
Tx Mode Selects the required transmission mode. The options are
2K and 8K.

Guard Interval

Selects the required guard interval. The options are 1/4,

1/8, 1/16, and 1/32.
Scan Starts or stops a service scan.

Information:
Modulation
The modulation type of the locked stream. The values can
be QPSK, QAM16 or QAM64.
FEC The FEC rate of the locked stream. The values can be 1/2,
2/3, 3/4, 5/6 or 7/8.
Network ID The network id of the locked stream.
Transport ID The transport id of the locked stream.
Services Found Number of services found on the locked stream after
a scan.
Services Added Number of services added to the system after a scan.
If some of the services found are already stored then
they will not be re-added.