beautypg.com

Maintenance and cleaning – Parkside PKZ 180 B2 User Manual

Page 11

background image

8

PKZ 180 B2

GB

using the adapter nozzle

Area of use:

You can insert the adapter nozzle in a vent
valve. You will fi nd this together with other valves
(standard valve, screw valve, ...) on large-volume
items, for example an infl atable mattress.

Press the lever quick coupler downwards to
attach it.

Insert the nozzle adapter into the lever quick
coupler and then release it.

Screw the nozzle adapter into the adapter
nozzle .

Infl ate as described above.

Maintenance and cleaning

WARNING! RISK OF INJURY! Switch
the appliance off and remove the
power plug before commencing any
work to the appliance.

Do not use any sharp objects to clean the
appliance. Never permit fl uids to penetrate
inside the appliance. The appliance could be
damaged. The carbon brushes should only be
replaced by the service centre or an authorised
specialist workshop. Apart from this, the appli-
ance is maintenance-free.

Ensure that the appliance has cooled down
completely, otherwise there is a risk of burns.

The appliance must be depressurised before
all cleaning and maintenance tasks. To do this,
open the release valve until no more air
escapes.

Clean the appliance regularly, preferably im-
mediately after completion of the work.

Clean the housing with a dry cloth – do NOT
use petrol, solvents or cleaners that can attack
the plastic.

Ensure that no water gets into the appliance.

Ventilation openings must never be obstructed.

NOTE

Replacement parts not listed (such as carbon
brushes, switch) can be ordered via our
service hotline.

NOTE

This appliance is maintenance free. Never open
the appliance. The appliance may only be re-
paired by an authorised service centre or Cus-
tomer Service. If one of the faults listed below
occurs, note the following:

Disconnect the appliance from any power
supply.

Allow the appliance to cool down and wait a
short while for the residual energy to neutralise.

Ensure that the appliance is in good working
condition.

Troubleshooting

Fault

Solution

1. Appliance

does not
run

1. Check your power supply.

Check that all cables, fuses
and the mains socket are in
working order.

2. Do not use excessively long

extension cables.

3. Do not use the appliance

at temperatures below
+5 degrees.

4. Avoid overheating the

motor. Allow the motor
to cool down.

2. Working

pressure
too low

Check the seals and the non-
return valve. Replace these if
necessary.

3. Tools do

not work

Check the hoses, quick coupler
and the tools. Replace these if
necessary.

IB_108972_PKZ180B2_LB4.indb 8

IB_108972_PKZ180B2_LB4.indb 8

13.01.15 08:56

13.01.15 08:56