GB

green LED lights up:

Charging is completed.

green LED flashes:

The battery voltage is < 12.5 V,

battery is pre-charged for

30 min.

LEDs flash red and green:

Defective battery installed,

no charging.

LEDs light up in red and green:

Rechargeable battery is too cold

or too hot.

After a cooling or heating period,

charging starts automatically.

Used batteries

• If a fully recharged battery lasts for

considerably shorter operating times,

the battery is used up and needs to be

replaced. Only use an OEM battery

pack replacement available from our

Customer Service.

• Always take heed of the applicable

safety instructions as well as the envi-

ronmental protection regulations and

information (see “Waste Disposal and

Environmental Protection”).

Assembly

Only insert the rechargeable

battery when the device is com-

pletely assembled. If the device

is switched on accidentally,

there is a danger of injury.

Installing/changing the

blade

Always wear protective gloves

when handling the saw blade in

order to avoid cutting yourself.

Caution, risk of Injury!

- Do not use any blunt or bent

blades or blades which are dam-

aged in any other way.

- Always insert a suitable saw

blade.

An overview of appropriate blades

can be found in “Spare Parts/Ac-

cessories”.

Installing the blade:

1. Turn the chuck ring (4) in the

direction of the arrow

and

insert the shank of the saw blade

(1) all the way into the slot of the

saw blade holder (3).

2. To lock, turn the chuck ring (4)

back to the starting position.

3. Check that the saw blade is se-

cure by pulling on it.

Removing the saw blade:

4. Turn the chuck ring (4) in the

direction of the arrow

and

pull the blade out of the saw

blade holder.

For certain work, the saw blade

can also be inserted after turning

through 180°.

Operation

When working with the de-

vice, always wear suitable

clothing and appropriate pro-

tective equipment.

Prior to each use it must be

ensured that the device is

working correctly.

Personal protective equip-

ment and a fully functional

device reduce the risk of inju-