beautypg.com

Assembly, Gb mt – Parkside PDOS 200 B2 User Manual

Page 57

background image

57

GB MT

a) Lung damage, if suitable respiratory

protection is not worn.

b) Hearing damage, if suitable ear protec-

tion is not worn.

c) Damages to health due to

- touching the area of the grinding tool

which was not covered;

- the ejection of pieces from workpiece

or damaged grinding discs.

d) Damage to your health caused by

swinging your hands and arms when

operating the appliance for longer pe-

riods of time or if the unit is not held or

maintained properly.

Warning! During operation, this

electric tool generates an electro-

magnetic field which, under certain

circumstances, may impair the func-

tionality of active or passive medical

implants. To reduce the risk of seri-

ous or lethal injuries, we recommend

that persons with medical implants

consult their doctor and the manufac-

turer of their medical implant before

operating the machine.

Assembly

Caution! Risk of injury!

- Ensure that you have sufficient

space in which to work, and that

you do not endanger other peo-

ple.

- Always fasten the device on to the

work surface with screws featuring

the sufficient length and thickness

in order to maintain control of the

device.

- All covers and protective devices

must be assembled properly be-

fore commissioning.

- Disconnect the mains plug before

changing the setting on the device.

• Make sure that the sparks produced

by grinding do not present a danger,

e.g. reach people or ignite flammable

substances.

• Always wear safety glasses, safety

gloves, respiratory protection and ear

protection when grinding, brushing

and separating.

• Never keep the fingers between the

grinding disc and spark protection

or in close proximity to the protective

hoods. There is a risk of crushing.

• The rotating parts of the device cannot

be covered due to functional reasons.

Therefore, proceed cautiously and hold

the workpiece firmly in order to avoid

slipping which could cause your hands

to come into contact with the grinding

disc.

• The workpiece gets hot during grind-

ing. Do not touch the machined area,

allow it to cool down. There is a risk

of burning. Do not use coolants or the

like.

• If you are tired or have consumed al-

cohol or tablets, do not work with the

device. Always have a break on time.

• Switch the device off and remove the

mains plug

- to loosen a blocked insertion tool,

- if the connection line is damaged or

entangled,

- in case of unusual sounds.

Residual risks

Even if properly operating and handling

this electric tool, some residual risks will

remain. Due to its construction and build,

this electric tool may present the following

hazards: