Change the oil after each season. To do this,
remove the old oil from the warm engine and
refill with new oil.

Remove the spark plug (fig. N / Pos. N1). Fill
about 20 ml of oil into the cylinder using an oil
can. Slowly pull the express start so that the oil
protects the cylinder from the inside. Screw the
spark plug back in.

Store the device in a well ventilated place or
area.

Preparation for transporting

Empty the petrol tank with a petrol suction pump
or alternatively using the petrol tap and a suita-
ble canister.

Once it it ready for use,

leave the engine running

until the rest of the petrol has been used up.

Empty the engine oil from the engine (as de-
scribed).

Remove the spark plug connector (Fig M) from
the spark plug.

Secure the device with a tension belt to prevent
it slipping out of place.

Ordering spare parts

When ordering replacement parts you should give
the following information:

Type of device

Device article number

Device ID number

Find current information at
www.kompernass.com

Disposal

The packaging is

made of environmentally friendly materi-
als. It can be disposed of at your local
recycling centre.

Do not dispose of

electric equipment in the household waste!

According to European Directive 2002 / 96 / EC,
used electrical devices must be collected and recy-
cled in an environmentally friendly manner.

Contact your local refuse disposal authority for more
details of how to dispose of your worn-out devices.

Troubleshooting guide

Fault

Cause

Remedy

Engine does

not start

Automatic oil

cut-out has not

responded

Check oil level,
top up engine oil

Spark plug

fouled

Clean or replace
spark plug
(electrode
spacing 0.6 mm)

No fuel

Refuel / have
the petrol cock
checked

Generator

has too little

or no voltage

Controller or

capacitor

defective

Contact your

dealer

Overcurrent

circuit-breaker

has triggered

Actuate the circuit-

breaker and reduce

the consumers

Air filter dirty

Clean or replace

the filter

Maintenance schedule

Please adhere to the following maintenance periods
in order to ensure a failure-free operation.

IMPORTANT! The equipment must be
filled with engine oil and fuel before it