Using the adapter set, Cleaning / care, Spare parts – Parkside PKZ 180 A1 User Manual
Page 41: Maintenance and service, Information about warranty and service processing
41
GB/MT
... / Cleaning / Care / Spare ... / Maintenance and ... /Information about ...
General safety information for electrical devices / Before use / Start-up
Using the adapter set
The adapter set allows the tyre filling device to be
used for the following additional applications:
a) Inflating balls using the ball needle
10
.
b) The valve adapter
11
allows bicycle tyres to be
inflated.
c) Inflating pools, air mattresses or dinghies using
the additional adapter
15
.
d) inflating items with screw valves (e.g. dinghies)
using the screw-on valve adapter
13
.
e) Deflating large-volume items. Use the deflating
valve adapter
12
for this purpose.
f) The two tapered universal adapters (
8
/
16
)
can also be used to inflate air mattresses.
Cleaning / Care
Note: We recommend cleaning the device imme-
diately after every use. Please first unplug from the
mains before cleaning.
Be sure the device is completely cooled off to
prevent burns.
Do not use cleaning agents or solvents for
cleaning.
Be sure water does not enter the device.
Depressurise the device before cleaning. To do
so, use the tyre filling device as a blow-out gun
and activate the trigger until no air escapes
anymore.
Note: Store the compressor in a dry and safe
environment. Bleed the device and any connected
air tools before storing.
Spare parts
Please contact our Service Department directly if
you are in need of spare parts.
www.cmc-creative.de
E-mail: [email protected]
Phone: +49 (0) 6894 9989752
Maintenance and Service
This device requires no maintenance.
Note: Never open the device. Any repairs must
be performed by our authorised service branch or
Customer Service.
Please note the following, if one of the errors below
occurs:
Disconnect the device from any power supply.
Allow the device to cool down and wait a
short period to neutralise residual energy.
Always verify the device is in safe working
condition.
Fault analysis
Fault
Solution
1. Compressor
doesn't start
1. Check the mains supply.
Check all cables, the fuse
and outlet are working.
2. Do not use extension ca-
bles which are too long.
3. Do not use the device in
ambient temperatures
below + 5 °C.
4. Avoid the motor overheat-
ing. Allow the motor to cool
down.
2. Insufficient
working pres-
sure
Check seals and the check
valve and have replaced, if
necessary
3. Tools aren't
working
Check hoses, quick-discon-
nect coupling and tools, and
have replaced if necessary
Information about warranty
and service processing
Creative Marketing Consulting GmbH
warranty
Dear customer, the warranty for this device is 3 years
from the date of purchase. In the event of product
defects, you have legal rights against the retailer of
this product. Your statutory rights are not limited in
any way by our warranty detailed below.
93472_Kompressor_PKZ_180_A1_Content_LB5.indd 41
13.11.13 17:02