beautypg.com

Operation – Parkside PHKS 1350 A1 User Manual

Page 11

background image

8

PHKS 1350 A1

GB

WARNING!

The arrow on the saw blade must corre-
spond to the arrow showing the direction of
rotation (running direction shown on the
device).

Ensure that the saw blade is suitable for the
rotational speed of the tool.

Mounting/setting the guide fence

Loosen the wing screw and insert the guide
fence into the guide fence slot .

Set the desired cut width with the help of the
scale on the guide fence and the marking
arrow in the base plate (see also Fig. B).

0

45

45

Fig. B: Cutting width 3 cm

Retighten the wing screw .

Connecting the sawdust extraction
appliance

Attach the adapter for dust extraction to the
chip ejector .

Connect an approved dust and chip extraction
device.

Operation

Switching on and off

Switching on:

Push the safety lock-out to the left or right
and keep it pressed.

Press the ON/OFF switch . Once the saw is
running you can release the safety lock-out .

Switching off :

Release the ON/OFF switch .

Setting the cutting angle

You can select the cutting angle with the help of the
cutting angle scale .

Release the wing screw on the cutting angle
preselector , set the desired angle on the
cutting angle scale and then re-tighten the
wing screw.

Setting the cutting depth

NOTE

We generally recommend setting the cutting
depth to approx. 3 mm more than the thickness
of the material. This ensures that you achieve
a clean cut.

Release the locking screw , set the desired
cutting depth on the cutting depth scale and
then re-tighten the locking screw .

Working with the circular saw

1. Switch on the device – as described in "Switching

on and off " – and then place it with the front
edge of the base plate on the material.

2. Align the machine using the guide fence or

by using a marked line.

3. Hold the machine in both hands using the

handles and saw by exerting an even pressure.

Switching the laser on and off

Switching on:

Press the ON/OFF switch laser .

Switching off :

Press the ON/OFF switch laser .

NOTE

If the batteries are spent, replace them with
two new 1.5 V alkaline button cells (type
AG 13/LR 44, e.g. GPA 76) .

IB_36453_PHKS1350A1_LB4.indb 8

IB_36453_PHKS1350A1_LB4.indb 8

28.04.14 08:35

28.04.14 08:35