Elinchrom RX 300 User Manual
Page 13
12
Flash power
J(Ws)
300
600
1200
Power supply 230V Version
V
all units 215-240
120V Version
V
all units 110-120
F-stop, 1m, 100 ISO, with reflector 48°
GN
64,1
90,1
128,1
Control range
J(Ws)
9-300
18-600
36-1200
Recycling time 230V Version
s
0,2-0,6
0,25-0,8
0,35-1,5
120V Version
s
0,25-1
0,3-1,6
0,35-2,8
Flash duration (t 0,5) 1/1
s
1/2850
1/2050
1/1450
(t 0,5) 1/32
s
1/1350
1/850
1/480
Modelling lamp 230V Version
W
250*/E27
250*/E27
300 GX 6,35
120V Version
W
150/BA15D 150/BA15D
250/BA15D
120V «Canada Version»
W
150/E27
150/E27
150/E27
Voltage across sync cable
V
5
5
5
Connected load A/VA
(W)
5/1150
6,3/1500
8/1840
Radio interference suppressiv CE-IEC 491 EN 60 555 - EN 61 000 - 4 - 2/3/4/5
Dimension length x diam.
cm
21x14
21x14
30x14
Weight
kg
2,15
2,45
3,45
Tolerances and specifications conforming to IEC and CE standards.
Technical data subject to change without notice.
* Optional alternative 300W/GX6.35
Features
• Locking bayonet ring for accessory and reflector fitting
• Tilthead whit 5/8" - inch stand socket
• Thermal safety
• User replaceable flash tube UV coated (5650°K)
• Halogen modelling lamp 250W, with E27 fitting, and
300W/GX6.35for Style 1200RX (230V Version)
• Silent fan cooling
• Controls for: modelling on/off, cell on/off, acoustic signal on/off.
• Flash and modelling power control.
• «X» synchro jack socket 3,5 mm.
• Socket for Plug-In remote control.
• Auto dumping function. Automatic discharge of flash power
• Central umbrella tube plus external fitting
• Acoustic recharging signal
• Mains cable
• Synchro cord of 5m (jack 3.5mm plug)
• Protective cover
• Total compatibility with all Elinchrom accessories
• Very fast recycling time
• Very short flash duration
Technical data
300RX
600RX
1200RX