Trouble shooting
Problem
Possible cause
Fault correction
Device does not start
Mains voltage is not present
Check plug socket, power cord,
line, plug and fuse, where ap-
propriate, repair through electri-
cal specialist
The equipment is not
switched on
Switch on the equipment (see
“switching on/off“)
Safety stop due to missing
or incorrectly inserted pleat-
ed filter ( 13) or metal
filter cage ( 14)
Insert the pleated filter correctly
(see “cleaning/maintenance“)
Defective on/off switch
( 6)
Repair through customer service
Defective motor
The single-use thermal fuse
has disconnected the power
circuit
Low or lack of suction
Suction hose ( 11) or suc-
tion tube ( 12) blocked
Remove obstructions and block-
ages
The metal container ( 10)
is not closed
Close the metal container
The metal container ( 10)
is full
Empty the metal container (see
“cleaning/maintenance“)
The pleated filter ( 13) is
clogged
Clean or replace the pleated
filter (see “cleaning/mainte-
nance“)
The air filter (
18) is
clogged
Clean the air filter (see “clean-
ing/maintenance“)
Pre-filter ( 15) is clogged Clean or replace pre-filter (see
"Cleaning/Maintenance")
Pre-filter ( 15) reduces
the suction power
To vacuum coarse dirt, remove
the pre-filter