4. Proper use
The equipment is designed for drilling work with
hammer action in concrete, rock and brick, al-
ways using the correct drill bit. The equipment is
also suitable for screwdriving and drilling in wood
and steel.
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the manufac-
turer will be liable for any damage or injuries of
any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
5. Technical data
Motor power supply: ................................. 18 V DC
Idling speed 1st gear:.......................... 0-300 min
-1
Idling speed 2nd gear: ........................ 0-900 min
-1
Battery capacitance: .................................... 1.5 Ah
Clockwise/counter-clockwise: .......................... Yes
Battery charge voltage: ............................. 18 V DC
Battery charge current: .............................1500 mA
Charging unit supply
voltage: ................................230-240V~ 50-60Hz
Weight: ...........................................................1.7 kg
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60745.
No-load operation
L
pA
sound pressure level .....................78,63 dB(A)
K
pA
uncertainty .................................................3 dB
L
WA
sound power level ......................89,63 dB(A)
K
WA
uncertainty ................................................3 dB
Hammer drilling in concrete
L
pA
sound pressure level .....................80,62 dB(A)
K
pA
uncertainty .................................................3 dB
L
WA
sound power level .......................91,62 dB(A)
K
WA
uncertainty ................................................3 dB
Wear ear-muffs.
The impact of noise can cause damage to hea-
ring.
Total vibration values (vector sum of three direc-
tions) determined in accordance with EN 60745.
No-load operation
Vibration emission value a
h
< 2.5 m/s
2
K uncertainty = 1.5 m/s
2
Hammer drilling in concrete
Vibration emission value a
h
= 5.767 m/s
2
K uncertainty = 1.5 m/s
2
Warning!
The specifi ed vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equip-
ment is used and may exceed the specifi ed value
in exceptional circumstances.
The specifi ed vibration value can be used to
compare the equipment with other electric power
tools.
The specifi ed vibration value can be used for initi-
al assessment of a harmful effect.
For the protection of the operator it is essential to
specify safety measures which are based on an
estimate of the exposure during the actual condi-
tions of use (all stages of the operating cycle must
be considered, e.g. times in which the electric
tools are switched off and times in which the tool
is switched on but operates without load).