Trouble shooting, Replacement parts – Parkside PNTS 1300 B2 User Manual
Page 11
11
GB
Trouble shooting
Problem
Possible.cause
Fault.correction
Device does not start
Mains voltage is not
present
Check plug socket, cable,
line, plug and fuse, where
appropriate, repair through
electrical specialist
Defective on/off switch
(
3)
Repair through customer
service
Worn carbon brushes
Defective motor
Low or lack of suction
Hose system (
13/14) or
jets (
18/19) blocked
Remove obstructions and
blockages
Suction pipe (
12)
assembled incorrectly
Assemble suction pipe correctly
Container (
6) open
Close container
Container (
6) full
Empty container
Filter (
15/16/17) full or
clogged
Empty, clean or replace filter
Ball on filter basket (
24)
incorrectly positioned (e.g.
due to jerky movements)
Switch off the equipment so the
ball drops then switch on again
Replacement parts
You can order replacement parts directly via our Service Centre (see page 61). Please state
the appliance type when placing an order.
Item. Description............................................................................ Product.No.
15
Foam filter, pack of 3 ................................................................. 30250130
17
Paper filter bags, pack of 5 ........................................................ 30250132
16
Material filter for dry vacuuming .......................................................30250131
20
Crevice nozzle ........................................................................... 72800039
13/14 Vacuum hose ............................................................................ 72800218
18
Floor nozzle ............................................................................... 72800217