11

GB

Trouble shooting

Problem

Possible.cause

Fault.correction

Device does not start

Mains voltage is not

present

Check plug socket, cable,

line, plug and fuse, where

appropriate, repair through

electrical specialist

Defective on/off switch

(

3)

Repair through customer

service

Worn carbon brushes

Defective motor

Low or lack of suction

Hose system (

13/14) or

jets (

18/19) blocked

Remove obstructions and

blockages

Suction pipe (

12)

assembled incorrectly

Assemble suction pipe correctly

Container (

6) open

Close container

Container (

6) full

Empty container

Filter (

15/16/17) full or

clogged

Empty, clean or replace filter

Ball on filter basket (

24)

incorrectly positioned (e.g.

due to jerky movements)

Switch off the equipment so the

ball drops then switch on again

Replacement parts

You can order replacement parts directly via our Service Centre (see page 61). Please state

the appliance type when placing an order.

Item. Description............................................................................ Product.No.

15

Foam filter, pack of 3 ................................................................. 30250130

17

Paper filter bags, pack of 5 ........................................................ 30250132

16

Material filter for dry vacuuming .......................................................30250131

20

Crevice nozzle ........................................................................... 72800039

13/14 Vacuum hose ............................................................................ 72800218

18