beautypg.com

Trouble shooting, Replacement parts – Parkside PNTS 1300 B2 User Manual

Page 10

background image

10

GB

Trouble shooting

Problem

Possible cause

Fault correction

Device does not start

Mains voltage is not present

Check plug socket, cable, line,

plug and fuse, where appropri-

ate, repair through electrical

specialist

Defective on/off switch

(

3)

Repair through customer service

Worn carbon brushes

Defective motor

Low or lack of suction

Hose system (

13/14) or

jets (

18/19) blocked

Remove obstructions and block-

ages

Suction pipe (

12) assem-

bled incorrectly

Assemble suction pipe correctly

Container (

6) open

Close container

Container (

6) full

Empty container

Filter (

15/16/17) full or

clogged

Empty, clean or replace filter

Ball on filter basket (

24)

incorrectly positioned (e.g.

due to jerky movements)

Switch off the equipment so the

ball drops then switch on again

Replacement parts

You can order replacement parts directly via our Service Centre (see page 12). Please

state the appliance type when placing an order.

Item Description ....................................................... Product No.

15 Foam filter, pack of 3 ...................................................... 30250101

16

Material filter for dry vacuuming ....................................... 30250135

17

Paper filter bags, pack of 5 .............................................. 30250134

20

Crevice nozzle ............................................................... 91099005

13/14 Vacuum hose ................................................................. 91099440

18

Floor nozzle ................................................................... 91099443