Trouble shooting
Problem
Possible cause
Fault correction
Device does not start
Mains voltage is not present
Check plug socket, cable, line,
plug and fuse, where appropri-
ate, repair through electrical
specialist
Defective on/off switch
(
3)
Repair through customer service
Worn carbon brushes
Defective motor
Low or lack of suction
Hose system (
13/14) or
jets (
18/19) blocked
Remove obstructions and block-
ages
Suction pipe (
12) assem-
bled incorrectly
Assemble suction pipe correctly
Container (
6) open
Close container
Container (
6) full
Empty container
Filter (
15/16/17) full or
clogged
Empty, clean or replace filter
Ball on filter basket (
24)
incorrectly positioned (e.g.
due to jerky movements)
Switch off the equipment so the
ball drops then switch on again
Replacement parts
You can order replacement parts directly via our Service Centre (see page 12). Please
state the appliance type when placing an order.
Item Description ....................................................... Product No.
15 Foam filter, pack of 3 ...................................................... 30250101
16
Material filter for dry vacuuming ....................................... 30250135
17
Paper filter bags, pack of 5 .............................................. 30250134
20
Crevice nozzle ............................................................... 91099005
13/14 Vacuum hose ................................................................. 91099440
18
Floor nozzle ................................................................... 91099443