Linx Technologies LICAL-TRC-MT User Manual
Page 15

–
–
–
–
24
25
MT Series T
ranscoder Activation Times and T
ransmitted Packet Duty Cycle
Confirmation
Custom Data
Transmission
Targeted
Device
Addr
essing
Baud Rate
(bps)
Packet Time
(ms)
Min Activation
Time (ms)
Max Activation
Time (ms)
TX Data Duty
Cycle (%)
O
ff
O
ff
O
ff
9,600
20.0
9.6
337.6
22.0
O
ff
O
ff
O
ff
28,800
11.3
5.0
170.0
18.6
On
O
ff
O
ff
9,600
23.0
9.6
337.6
19.1
On
O
ff
O
ff
28,800
11.0
5.0
170.0
19.1
O
ff
On
O
ff
9,600
21.3
11.0
339.0
23.2
O
ff
On
O
ff
28,800
11.9
5.7
170.7
19.3
On
On
O
ff
9,600
24.4
11.0
339.0
20.3
On
On
O
ff
28,800
11.6
5.7
170.7
19.8
O
ff
O
ff
On
9,600
23.8
13.8
341.8
25.6
O
ff
O
ff
On
28,800
12.9
7.0
172.0
20.9
On
O
ff
On
9,600
27.2
13.8
341.8
22.4
On
O
ff
On
28,800
12.9
7.0
172.0
20.9
O
ff
On
On
9,600
25
15.1
343.1
26.6
O
ff
On
On
28,800
13.4
7.6
172.6
21.6
On
On
On
9,600
28.6
15.1
343.1
23.3
On
On
On
28,800
13.6
7.6
172.6
21.3
Minimum Activation time without T
ransceiver Power Contr
ol
Maximum Activation time with T
ransceiver Power Contr
ol
Figure 19: MT Series Transcoder Activation Times and Transmitted Packet Duty Cycle
MT Series T
ranscoder Restor
e Default Serial Interface Engine Command
Definition
Command
Reply
Restor
e Default
0x00 -
0xFF
- 0x52 - 0x73 - 0x74 - 0x4D - 0x54 - 0xFF
0x00 - 0x41 - 0x43 - 0x4B - 0xFF
MT Series T
ranscoder Serial Interface Engine Timings (ms)
SER_IO = Input
SER_IO = Output
Definition
Min
Ready
Max
Ready
Receive
Cmd
Pr
ocess
Cmd
Reply
W
ait
Transmit
Reply
Finish
Pr
ocess
Min T
otal
Time
Max T
otal
Time
Restor
e Default
(9,600bps)
0.08
33.00
8.30
1.07
4.00
5.29
870.00
890.00
925.00
Restor
e Default
(28,800bps)
0.08
17.00
2.80
1.07
4.00
1.73
870.00
880.00
900.00
Figure 20:
MT SeriesT
ranscoder Restore Default Serial Interface Eng
ine Command
Figure 21:
MT Series
Transcoder Serial Interface Eng
ine
Timings (ms)