3
ES Series Receiver Specifications
Parameter
Symbol
Min.
Typ.
Max.
Units
Notes
Power Supply
Operating Voltage
V
CC
4.5
5.0
5.5
VDC
Supply Current
I
CC
5.5
6.0
6.5
mA
Power-Down Current
I
PDN
50.0
µA
4
Receiver Section
Receive Frequency
F
C
RXM-869-ES
869.85
MHz
RXM-916-ES
916.48
MHz
Center Frequency
Accuracy
–60
+60
kHz
LO Frequency
RXM-869-ES
859.15
MHz
RXM-916-ES
905.78
MHz
IF Frequency
F
IF
10.7
MHz
Spurious Emissions
–75
–50
dBm
1
Receiver Sensitivity
–92
–97
–102
dBm
2
Noise Bandwidth
N
3dB
280
kHz
Audio Bandwidth
20
28,000
Hz
3,4
Audio Output Level
360
mV
P-P
4,5
Data Rate
200
56,000
bps
4
Electrical Specifications
Ordering Information
Ordering Information
Part Number
Description
TXM-869-ES
ES Series Transmitter 869MHz
TXM-916-ES
ES Series Transmitter 916MHz
RXM-869-ES
ES Series Receiver 869MHz
RXM-916-ES
ES Series Receiver 916MHz
EVAL-***-ES
Basic Evaluation Kit
MDEV-***-ES
Master Development System
*** = Frequency
Receivers are supplied in tubes of 40 pcs.
Figure 2: Ordering Information
ES Series Receiver Specifications
Parameter
Symbol
Min.
Typ.
Max.
Units
Notes
Data Output
Logic Low
V
OL
0.0
0.1
VDC
Logic High
V
OH
V
CC
– 1.1
V
CC
– 1
V
CC
– 0.9
VDC
Power Down Input
Logic Low
V
OL
0.0
0.8
VDC
Logic High
V
OH
2.8
V
CC
VDC
RSSI
Dynamic Range
60
dB
4
Gain
30
mV/dB
4
Voltage with No Carrier
1.1
V
4
Voltage with No Carrier
2.9
V
4
Antenna Port
RF Input Impedance
R
IN
50
Ω
4
Timing
Receiver Turn-On Time
Via V
CC
3.8
4.7
5.4
mS
4,6
Max Time Between
Transitions
0
5.0
mS
4,7
Environmental
Operating Temperature
Range
0
+70
ºC
4
1. Into a 50-ohm load.
2. For 10
-5
BER at 9,600 baud.
3. The audio bandwidth is wide to
accommodate the needs of the data
slicer. In audio applications, audio
quality may be improved by using
a low-pass filter rolling off at the
maximum frequency of interest.
4. Characterized, but not tested.
5. Input frequency deviation-dependent.
6. Time to receiver readiness from the
application of power to V
CC
or PDN
going high.
7. Maximum time without a data
transition.
Figure 3: Electrical Specifications
Warning:
This product incorporates numerous static-sensitive
components. Always wear an ESD wrist strap and observe proper ESD
handling procedures when working with this device. Failure to observe