beautypg.com

Ordering information, Absolute maximum ratings, Electrical specifications – Linx Technologies TRM-xxx-NT User Manual

Page 4

background image

– –

– –

2

3

NT Series Transceiver Specifications

Parameter

Symbol

Min.

Typ.

Max.

Units Notes

Power Supply

Operating Voltage

V

CC

2.5

5.5

VDC

TX Supply Current

l

CCTX

At +12.5dBm

36

40

mA

1,2

At 0dBm

16

21

mA

1,2

RX Supply Current

l

CCRX

19

21

mA

1,2

Power-Down Current

l

PDN

1.0

µA

1,2

Standby Current

l

STD

1.4

2.5

mA

1,2

RF Section

Center Frequency Range

F

C

TRM-868-NT

863

870

MHz

3

TRM-900-NT

902

928

MHz

3

Center Frequency Accuracy

–5

+5

kHz

2

Number of Channels

TRM-868-NT

8/68

3, 10

TRM-900-NT

8/101

3,10

Channel Spacing

250

kHz

3

Data Rate

Baud Band = 1

1

19.2

kbps

11

Baud Band = 2

19.2

80

kbps

11

Baud Band = 3

80

160

kbps

11

Baud Band = 4

160

300

kbps

11

Receiver Section

IF Frequency

F

IF

Baud Band = 1

200

kHz

4,11

Baud Band = 2

200

kHz

4,11

Baud Band = 3

200

kHz

4,11

Baud Band = 4

300

kHz

4,11

Spurious Emissions

−62

dBm

Receiver Sensitivity

Baud Band = 1

−111

−113

dBm

5,11

Baud Band = 2

−108

−110

dBm

5,11

Baud Band = 3

−104

−106

dBm

5,11

Baud Band = 4

−100

−102

dBm

5,11

Electrical Specifications

Ordering Information

Absolute Maximum Ratings

Figure 2: Ordering Information

Figure 3: Absolute Maximum Ratings

Ordering Information

Part Number

Description

TRM-868-NT

868MHz NT Series Transceiver

TRM-900-NT

900MHz NT Series Transceiver

MDEV-868-NT

868MHz NT Series Master Development System

MDEV-900-NT

900MHz NT Series Master Development System

Transceivers are supplied in tubes of 18 pcs.

Absolute Maximum Ratings

Supply Voltage V

cc

−0.3

to

+5.5

VDC

Any Input or Output Pin

−0.3

to

V

CC

+ 0.3

VDC

RF Input

0

dBm

Operating Temperature

−40

to

+85

ºC

Storage Temperature

−55

to

+125

ºC

Exceeding any of the limits of this section may lead to permanent damage to the device.
Furthermore, extended operation at these maximum ratings may reduce the life of this
device.