Installation

4.4. Multiple FSP Amplifier Installation

When installing multiple FSP Amplifiers side by side in a control panel, observe
the following:

30mm(1.2in.)or more

o

r

m

o

re

5

0

m

m

(2

in

.)

o

r

m

o

re

5

0

m

m

(2

in

.)

C

3

N

1

N

C

2

N

C

C

3

N

1

N

C

2

N

C

C

3

N

1

N

C

2

N

C

N

C

N

C

3

1

C

2

N

FAN

30mm(1.2in.)or more

10mm(0.4in.)or more

FAN

4.4.1 Where Mounted Side by Side

When installing FSP Amplifiers side by side, provide at least 10 mm (0.4 in) space
between them and at least 50 mm (2 in) space above and below them as shown in the
figure above. Install cooling fans above the FSP Amplifiers to prevent the
temperature around each FSP Amplifier from increasing excessively and also to

maintain the temperature inside the control panel evenly.

4.4.2 Environment Inside Control Box

M aintain the following conditions inside the control box:

Ambient temperature for FSP Amplifier: 0 to 55

ο

C

Humidity: 90% RH or less, no condensing.
Vibration: 4.9 m/s

2

No freezing.
Ambient temperature to ensure long-term reliability: 45

ο

C or less

23