beautypg.com

Test procedures – Electrolux MICROMAT 153 E User Manual

Page 28

background image

Cooking charts and tips

28

Test procedures

(Microwave output power 900 Watt)
The quality and operation of microwave ovens are established by
recognised test institutes by testing specific dishes.

DIN

Power

Time

Standing

Comments

1)

Nr. 44 566

(mins)

time

Part 2

(mins)

Defrost and cook

900 Watt

7-9

3

Cover. Halfway through

fish fillet

cooking turn fillets so that
inner edges face outwards.

IEC 705

Power

Time

Standing

Comments

1)

(mins)

time
(mins)

Egg custard

350 Watt

16-18

120

(test A)

Sponge mixture

900 Watt

5-6

5

(test B)
Meat loaf (test C)

900 watt

11-13

5

Defrost minced

150 Watt

12-14

5

Place directly on turntable.

meat

Turn over halfway through.

Defrost raspberries 150 Watt

6-8

3

Cover.

1)

Place directly on turntable unless otherwise instructed. The turntable has to be
switched on.

MC 153 E UK,Plug 25/10/99 1:17 pm Page 28