beautypg.com

Energizer 509 User Manual

Energizer no. 509, Engineering datasheet, Industry standard tests (21°c)

background image

6V

Chemical System:

"Carbon Zinc" CLASSIC
Zinc-Manganese Dioxide (Zn/MnO

2

)

Designation:

ANSI-908, IEC-4R25

Nominal Voltage:

6.0 volts

Operating Temp:

-18°C to 55°C (0°F to 130°F)

Typical Weight:

600 grams (21.2 oz.)

Typical Volume:

492 cubic centimeters (30 cubic inches)

Jacket:

Plastic

Effects of Storage at Various Temperatures

Industry Standard Tests (21°C)

This data sheet contains typical information specific to batteries manufactured at the time of its publication.

Important Notice

ENERGIZER NO. 509

Specifications

mm (inches)

(No Added Mercury or Cadmium)

Industry Standard Dimensions

Storage/Capacity Characteristics

ENGINEERING DATASHEET

EVEREADY BATTERY COMPANY, INC.

www.energizer.com

1-800-383-7323 / USA
1-800-383-7323 / CANADA

1-800-383-7323 / USA - CANADA

+ 44 (0) 208 920 2306 / EUROPE

50

60

70

80

90

100

0

2

4

6

8

10

12

Pe

rf

o

rm

a

n

ce

R

e

te

nt

io

n (

%

)

Storage Time (years)

40°C

21°C

0°C

2.8

3.6

4.4

5.2

6.0

0

2

4

6

8

10

12

Vol

ta

g

e

(

CCV)

Service (hours)

LIGHTING

9.1 ohm 30 min/hr - 8 hrs/day

2.8

3.6

4.4

5.2

6.0

0

10

20

30

40

50

Vol

ta

g

e

(

CCV)

Service (hours)

LIGHTING

33 ohm 30 min/hr - 8 hrs/day

2.8

3.6

4.4

5.2

6.0

0

35

70

105

140

175

210

Vol

ta

g

e

(

CCV)

Service (hours)

BARRICADE FLASHER

110 ohm 12 hrs/day

23.00 (0.906)

27.00 (1.063)

68.20 (2.685)
65.00 (2.559)

115.00 (4.528)
107.00 (4.213)

68.20 (2.685)
65.00 (2.559)

103.20 (4.063)

96.00 (3.780)

Form No. EBC - 3105C

Page 1 of 2