Energizer 509 User Manual
Energizer no. 509, Engineering datasheet, Industry standard tests (21°c)
6V
Chemical System:
"Carbon Zinc" CLASSIC
Zinc-Manganese Dioxide (Zn/MnO
2
)
Designation:
ANSI-908, IEC-4R25
Nominal Voltage:
6.0 volts
Operating Temp:
-18°C to 55°C (0°F to 130°F)
Typical Weight:
600 grams (21.2 oz.)
Typical Volume:
492 cubic centimeters (30 cubic inches)
Jacket:
Plastic
Effects of Storage at Various Temperatures
Industry Standard Tests (21°C)
This data sheet contains typical information specific to batteries manufactured at the time of its publication.
Important Notice
ENERGIZER NO. 509
Specifications
mm (inches)
(No Added Mercury or Cadmium)
Industry Standard Dimensions
Storage/Capacity Characteristics
ENGINEERING DATASHEET
EVEREADY BATTERY COMPANY, INC.
www.energizer.com
1-800-383-7323 / USA
1-800-383-7323 / CANADA
1-800-383-7323 / USA - CANADA
+ 44 (0) 208 920 2306 / EUROPE
50
60
70
80
90
100
0
2
4
6
8
10
12
Pe
rf
o
rm
a
n
ce
R
e
te
nt
io
n (
%
)
Storage Time (years)
40°C
21°C
0°C
2.8
3.6
4.4
5.2
6.0
0
2
4
6
8
10
12
Vol
ta
g
e
(
CCV)
Service (hours)
LIGHTING
9.1 ohm 30 min/hr - 8 hrs/day
2.8
3.6
4.4
5.2
6.0
0
10
20
30
40
50
Vol
ta
g
e
(
CCV)
Service (hours)
LIGHTING
33 ohm 30 min/hr - 8 hrs/day
2.8
3.6
4.4
5.2
6.0
0
35
70
105
140
175
210
Vol
ta
g
e
(
CCV)
Service (hours)
BARRICADE FLASHER
110 ohm 12 hrs/day
23.00 (0.906)
27.00 (1.063)
68.20 (2.685)
65.00 (2.559)
115.00 (4.528)
107.00 (4.213)
68.20 (2.685)
65.00 (2.559)
103.20 (4.063)
96.00 (3.780)
Form No. EBC - 3105C
Page 1 of 2