Features, Instrument cluster, Rider information center – Polaris 2015 600 Switchback Assault User Manual
Page 48: Diagnostic codes

46
FEATURES
Instrument Cluster
Rider Information Center
Diagnostic Display Code Definitions
Open Load: There is a break in the wires that lead to the item listed in
the chart (injector, fuel pump, etc.), or the item has failed.
Short-to-Ground: The wire is shorted to ground between the electronic
control unit and the item listed in the chart.
Shorted Load: The wires leading to the item listed in the chart are
shorted together, or the item has shorted internally.
Short-to-Battery: The wire leading from the item listed in the chart to
the electronic control unit is shorted to a wire at battery voltage.
Diagnostic Codes
Component
Condition
SPN
FMI
Throttle Position Sensor
Voltage Too High
51
3
Voltage Too Low
4
Abnormal Rate of Change
10
Vehicle Speed Sensor
Data Erratic, Intermittent or Missing
84
2
Intake Air Temperature Sensor
Voltage Too High
105
3
Voltage Too Low
4
Barometric Pressure Sensor
Voltage Too High
108
3
Voltage Too Low
4
Engine Temperature Sensor
Voltage Too High
110
3
Voltage Too Low
4
Temperature Too High
16
Engine Overheat Shutdown
0
Temperature Above Normal Range
15
Alternator Power Supply
Potential (DC Chassis Voltage)
Voltage Too High
167
3
Voltage Too Low
4
Exhaust Temperature Sensor
Voltage Too High
173
3
Voltage Too Low
4
- 2015 800 Switchback Assault 2014 600 Switchback Assault 2014 800 Switchback Assault 2013 800 Switchback Assault 2011 800 Switchback Assault 2011 800 RMK 2011 800 Pro-RMK 2011 800 RMK Assault 2014 600 RMK 2014 600 Pro RMK 2014 800 RMK 2014 800 Pro RMK 2014 800 RMK Assault 2013 600 RMK 2013 600 Pro RMK 2013 800 RMK 2013 800 Pro RMK 2013 800 RMK Assault 2012 800 Switchback Assault 2012 600 RMK 2012 600 Pro RMK 2012 800 RMK 2012 800 Pro RMK 2012 800 RMK Assault