Warm weather starting procedure (above 40 ° f) – Polaris 1999 XLT Special User Manual
Page 3

3
1999 XLT Special
Engine Model: EC58PL160
AMBIENT
TEMPERATURE
Below -20°F
Below -29°C
-20°F to
+10°
-29°C to
-12°C
+10°F - +40°F
-12°C - +5°C
Above +40°F
Above +5°C
0-900
(0-3000)
380
360
340
330
Altitude
Meters
(F
)
900-1800
(3000-6000)
350
330
320
300
(Feet
)
1800-2700
(6000-9000)
320
300
290
270
2700-3700
(9000-12000)
290
280
270
250
- Shaded zone should drop Jet Needle one position (raise E-Clip)
- Production Setting
Warm Weather Starting Procedure (above 40° F)
In warmer temperatures, using full choke may cause the engine to “flood”, even if the engine is “cold”. Use the follow-
ing procedure to prevent this from happening.
1. Turn key to “On”.
2. Pull kill switch (shut - off switch) up to “run” position.
3. Flip choke toggle to “Half On” position.
4. Grasp starter handle and pull slowly until recoil engages; then pull to start.
If engine does not start in 3 pulls, flip choke toggle to “Off” position and slightly depress the throttle (no more than 1/4²
open), then pull to start. As soon as the engine starts, release the throttle.
PN 9914857 Rev 02 7/98