beautypg.com

Vertical interval trigger – Grass Valley TTN-BDS-0808CP User Manual

Page 17

background image

BDS-0808CP

Rev. 2


9


5 5 5 5
6 6 6 6
7 7 7 7
8 8 8 8

Serial Digital Video 4 layer

SDV layer 1 Input

SDV layer 1 Output

1 1 1 1
2 2 2 2

SDV layer 2 Input

SDV layer 2 Output


3 3 3 3
4 4 4 4

SDV layer 3 Input

SDV layer 3 Output


5 5 5 5
6 6 6 6

SDV layer 4 Input

SDV layer 4 Output


7 7 7 7
8 8 8 8

5.3 Vertical interval trigger
The BDS-0808CP router provides vertical interval switching. If vertical interval switching is desired you
have to connect an analogue VIT reference signal to the VIT input.

Switch 7 on the configuration switch enables or disables the VIT sensing on the VIT input. If VIT
switching is enabled but a proper signal is missing, the router will automatically switch without VIT.

The VIT can be switched according to the following pattern:

-

means switch down

*

means switch up


Switch

7 VIT


- disabled
* enabled

Default is VIT enabled.