beautypg.com

Connecting the bes-6464/110 to your pc, Selection of router level, Pin-out of rs-232 connector – Grass Valley TTN-BES-6464/110 User Manual

Page 11: Maximum cable length

background image

BES-6464/110

Rev. 1


3

3 Connecting the BES-6464/110 to your PC


For connection to a PC with Triton Router Control System, the RS-232 interface is used. The RS-232 port
on all Triton devices uses the standard DCE pin-out, see pin-out table under 4.3.
A standard modem cable can be used for connecting the router to the PCs serial port.

3.1 Selection of router level
The router level depends on the system configuration the router is going to work with. See chapter 5 for
more information. All routers are delivered with default level 1. Triton Router Control System offers the
control of up to 16 different routers or combinations of routers.

3.2 Pin-out of RS-232 connector
The DB9 female connector for the RS-232 port has the following pin-out:

Pin

2

Tx

Pin

3

Rx

Pin

5

GND

3.3 Maximum cable length
The maximum cable length for an RS-232 connection is per definition 15m. Longer distances can be
installed depending on the environmental conditions of the installation site. It is the responsibility of the
installer / user to secure a proper installation of the RS-232 connection.