Specifications, Mechanical, Environmental – Grass Valley TRX-PS-BU Series User Manual
Page 23: Air intake/exhaust locations, Appendix a — specifications, Appendix, Mechanical environmental
TRX-PS-BU Series Installation Manual
23
Appendix
A
Specifications
Mechanical
Environmental
Air Intake/Exhaust Locations
All modules draw cooling air through fans in the front. Warm air is
exhausted through openings in the back. It is not necessary to leave open
space above or below the chassis.
Table 3. Mechanical Specifications
Depth
,
a
a
Allow a minimum of 6 in. (152 mm) of clear space at the rear of the MCP for proper cable clearance and air flow.
Width
Height
Weight
b
b
All weights approximate.
Rack Units
TRX-PS-BU1200
11.56 in. / 294 mm
19.0 in. / 483 mm
1.75 in. / 44 mm
7.2 lb. / 3.2 kg
1
TRX-PS-BU2400
11.56 in. / 294 mm
19.0 in. / 483 mm
1.75 in. / 44 mm
10.3 lb. / 4.6 kg
1
TRX-PS-BU3600
11.56 in. / 294 mm
19.0 in. / 483 mm
1.75 in. / 44 mm
13.5 lb. / 6.1 kg
1
Table 4.
Environmental Characteristics (operation with required forced air cooling)
Operating temperature
32 to 158 degrees F (0 to 70 degrees C) ambient
Full specifications met
32 to 122 degrees F (0 to 50 degrees C)
Storage temperature
-40 to 185 F (-40 to +85 degrees C)