LED Display Operation

Rattler Tx Unit

Fig. 2-3: Rattler Tx Unit LEDs

1 Power LED – indicates power is connected and within 5-16 VDC range

2 SIG LED – indicates HD/SDI Signal Presence

Rattler Rx Unit

Fig. 2-4: Rattler Rx Unit LEDs

1 Power LED – indicates power is connected and within 5-16 VDC range

2 Sig Strength LED Display – indicates Received Optical Signal Strength from -20 dBm to

0 dBM

Fiber Optic Signal Strength measurement is explained further in

Fiber Optical Channel

Monitoring using the LED Display

on page 14.

See below for examples of signal strength indications.

Two LEDs lit indicate a signal strength
between -15 dBm and -10 dBm

Four LEDs lit indicate a signal strength
between -5 dBm and 0 dBm

Fig. 2-5: LED indications

The Rattler 4 will indicate a non-standard temperature reading if the LEDs begin to blink all
On and all Off.

Fig. 2-6: non-standard temperature LEDs

If the Rattler unit internal temperature drops below -30 degrees C or above 65 degress C,
the blinking LED indicator will start. At these extreme temperatures, unit performance will
be degraded or cease to function.