0 specifications – Grass Valley ADC-191p User Manual
Page 11

Guide to Installation and Operation
ADC-191p | 7
5.0 Specifications
Input
Signal:
Y, B-Y, R-Y 1 Vp-p nominal
with
sync
Return loss:
> 35 dB up to 5 MHz
Connector:
3 captive cables with 75
Ω male
BNCs
Output
Signal:
4:2:2 SMPTE 259M-C (270 Mbps)
Return loss:
> 15 dB up to 270 MHz
Jitter:
< 10 ns p-p
Connector :
75
Ω BNC
Processing performance
Signal path:
10 bits
Quantization:
12 bits
Freq. response:
±0.5 dB to 5 MHz
Processing delay:
3 lines
Electrical
Voltage requirement:
+5 VDC
Power consumption:
<3 W
Power connector:
Mini XLR-3
Mechanical
Overall size:
102 mm x 25 mm x 18 mm
(4” x 1” x 0.7”)
Power cable length:
127 mm (5”)
Full spec. temp. range: 0° C (32° F) to 30° C (86° F)
See also other documents in the category Grass Valley Equipment:
- LDK 5302 (24 pages)
- SFP Optical Converters (18 pages)
- 2000GEN (22 pages)
- 2011RDA (28 pages)
- 2010RDA-16 (28 pages)
- 2000NET v3.2.2 (72 pages)
- 2000NET v3.1 (68 pages)
- 2020DAC D-To-A (30 pages)
- 2000NET v4.0.0 (92 pages)
- 2020ADC A-To-D (32 pages)
- 2030RDA (36 pages)
- 2031RDA-SM (38 pages)
- 2041EDA (20 pages)
- 2040RDA (24 pages)
- 2041RDA (24 pages)
- 2042EDA (26 pages)
- 2090MDC (30 pages)
- 2040RDA-FR (52 pages)
- LDK 4021 (22 pages)
- 3DX-3901 (38 pages)
- LDK 4420 (82 pages)
- LDK 5307 (40 pages)
- Maestro Master Control Installation v.1.5.1 (455 pages)
- Maestro Master Control Installation v.1.5.1 (428 pages)
- 7600REF Installation (16 pages)
- 7600REF (84 pages)
- 8900FSS (18 pages)
- 8900GEN-SM (50 pages)
- 8900NET v.4.3.0 (108 pages)
- Safety Summary (17 pages)
- 8900NET v.4.0.0 (94 pages)
- 8906 (34 pages)
- 8911 (16 pages)
- 8900NET v.3.2.2 (78 pages)
- 8914 (18 pages)
- 8912RDA-D (20 pages)
- 8916 (26 pages)
- 8910ADA-SR (58 pages)
- 8920ADC v.2.0 (28 pages)
- 8920ADC v.2.0.1A (40 pages)
- 8920DAC (28 pages)
- 8920DMX (30 pages)
- 8920ADT (36 pages)
- 8920MUX (50 pages)
- 8921ADT (58 pages)