Chassis address setting requirement, Chassis address setting – Grass Valley PFR 500/E Dec 12 2002 User Manual

Page 26

background image

Chapter 2 PFR500/E Installation Information

26

PFR 500/E Instruction Manual

20 September 2002

Chassis address setting requirement

Each PFR500/E storage chassis has a chassis address switch that must be set to a unique
chassis address. Valid chassis addresses are 0-9 with 0 being reserved for the PFR500
RAID Chassis. All chassis are shipped with the chassis address set to 0.

The chassis address switch is located inside the chassis on the midplane board. The
following figures show how to gain access to the switch by removing the board canisters.

CAUTION: Refer to the PVS Series Installation Guide

you received with your Profile XP

storage system or the Media Area Network Instruction Manual for step-by-step
instructions for setting the chassis address.

The midplane is at the back of the slot that held the LBB canisters. On the midplane is a
small, white rotary switch.

.

3001

LBB A goes
in the bottom slot

LBB B goes
in the top slot

2796