Installation and Network Requirements
Configuration Guidelines
6
Configuration Guidelines
Miranda Imaging Frames (Symphonie or Quartet 2)
• iControl Solo supports a maximum of 100 Miranda interface cards (Densité and Imaging
combined).
• Quartet 1 and Solo frames are not supported.
• A maximum of four frames can be connected to each RS-422 communication port.
• When critical on-air equipment is controlled (e.g. incoming feeds) do not connect more
than two frames per RS-422 communication port.
• When using Symphonie frames that are fully loaded with XVP-801/811 and/or DAP-781
cards, do not connect more than one frame per RS-422 communication port.
Miranda Densité Frames
• iControl Solo supports a maximum of 100 Miranda interface cards (Densité and Imaging
combined).
• Thumbnail, audio level, closed captioning, and other similar probing features are not
supported in iControl Solo.
• Each frame must be registered to a single iControl Solo application. Ensure that the frame
is not registered to an iControl Application Server RCP-100 or RCP-200 device. Having the
same frame report to multiple Densité Managers may result in repeated loss of connection
and system instability. The Densité Controller only supports one client connection at a
time.