Module installation – Grass Valley 8980TLS User Manual
Page 11
8980TLS Instruction Manual
5
Installation
Module Installation
There are ten cell locations in the frame to accommodate either analog or
digital modules. These are the left ten locations. Refer to
The two cells on the right are allocated for the power supplies. For addi-
tional information concerning the Power Supply module, refer to the
Power Supply manual.
The third cell from the right is allocated for the Controller module. This
module provides the interface for the forced air cover, as well as the SMPTE
269M fault reporting (health alarm) and EDH network. For additional
information concerning the Controller module, refer to the Controller
manual.
Figure 3. 8900 Series Frame
To install a module into the frame, follow these steps:
1.
Insert the module into the frame, connector end first, with component
side of the module facing to the right and ejector tab to the top.
2.
Verify that the module connector seats properly against the backplane.
3.
Press the ejector tab in to seat the module in place.
Controller
Module
(only)
Any 8900 Module
Power
Supplies
(only)
0515_04