Module Alignment
SMPTE Alarm
Note
The SMPTE alarm can function only if the Frame Controller or 8900NET
module is installed in the frame (
).
for the SMPTE alarm functions activated by the 8941.
Module Alignment
This section contains:
•
Alignment Equipment
•
EQ Warning Adjustment
•
Output Gain Adjustment
Alignment Equipment
The 8941 module is fully aligned at the factory and normally requires no
adjustment in the field. If adjustments are necessary, they should be per-
formed only by qualified technicians using, at a minimum, the following
equipment (or equivalents):
•
270 Mb/s serial digital video test signal source with pathological test
signal and EDH
•
Tektronix WFM601 Waveform Monitor (or equivalent)
•
Analog Waveform Monitor
•
NTSC (525): Tektronix 1780 (or equivalent)
•
PAL (625): Tektronix 1781 (or equivalent)
•
300 meters Belden 8281 cable (or equivalent)
Table 3. SMPTE Alarm
Function
Alarm
No + 5V, +12V, or –12V
Full alarm
No video (if enabled)
Pulsing alarm
EQ warning (if enabled)
Pulsing alarm
Missing EAV or SAV
Pulsing alarm