beautypg.com

Module configuration, Automatic mode, Manual mode – Grass Valley 8936 User Manual

Page 11

background image

8936 Instruction Manual

5

Module Configuration

Module Configuration

When installing the 8936 module, there is an eight position DIP switch (S1)
that must be checked and/or set.

DIP switch S1 determines if automatic or manual data rate selection mode
is desired. It also determines if the EQ warning alarm and video present
alarm will be indicated on the health alarm line. Refer to Figure 4 for the
location of S1 and the possible settings.

Figure 4. S1 Settings

Refer to

Table 2

for the functions and descriptions of S1 settings.

Automatic Mode

In the automatic mode, the type of signal present is indicated by one of four
signal present LEDs. If there is not a signal present, no LEDs will illumi-
nate. Refer to

Figure 4

for the switch settings for the automatic mode.

Manual Mode

In the manual mode, the module will stay in the mode selected. The signal
present LEDs will only illuminate if that particular signal is present. Refer
to

Figure 4 on page 5

for the switch settings for the manual mode.

Note

For S1-1 through S1-4, only one signal selection switch can be turned on at
a time for proper operation.

Table 2. DIP Switch S1 Functions

S1 Switch #

Function

Description

1 – 4

Auto data rate selection

All up puts module in automatic data rate selection mode

1

143 Mb

When down, 143 Mb data rate is selected

2

177 Mb

When down, 177 Mb data rate is selected

3

270 Mb

When down, 270 Mb data rate is selected

4

360 Mb

When down, 360 Mb data rate is selected

5

EQ Warning

When down, EQ Warning Alarm is deacitvated (Off)

6

Video Present

When down, Video Present Alarm is deacitvated (Off)

7 – 8

Not Used

8936

S1

8

7

6

5

4

3

2

1

8110-09