Archgard 10-1800P User Manual
Page 27
Chalet 1800
27
TROUBLESHOOTING
PROBLEM
CAUSE
CURE
Glass is Dirty
1. Wood is wet
Use dry wood
2. Turning down air control or
damper too soon
Do not turn down until:
❖
there is a good bed of coals
❖
the wood is charred
3. Draft too low – Improper
chimney height and / or di-
ameter
Flue pipe too long, too many
offsets or too large a diame-
ter
❖
Chimney plugged or restricted,
check flue
❖
Provide outside air for combus-
tion
4. Door gasket leakage
❖
Replace gasket
❖
Check latch
5. Excessive Creosote Buildup
See 1,2,3, above
Low Heat Output
1. Wood is wet
Use dry wood
2. Fire too small
Build a larger fire
3. Draft too low
Chimney plugged or restricted,
inspect and clean (See 3 above)
Won't Burn Overnight
1. Air control is set too high
Set control lower
2. Not enough wood
Un-split wood is preferred for over-
night burns
3. Draft too high
Excessive chimney height and / or
diameter
Stove Won't Burn
1. Combustion air supply
blocked
❖
Check outside air supply for ob-
struction
❖
Check that room air cover is
removed
2. Draft too low
❖
Chimney plugged or restricted,
inspect and clean
❖
Chimney / flue pipe oversized
or otherwise unsuitable