Optima 40 - sb – Archgard 40-DVI40N User Manual
Page 10

Optima 40 - SB
10
LEVELING THE OPTIMA 40-SB DIRECT VENT INSERT
Before placing the appliance into the fireplace, check the hearth of the fireplace to see if it is
level with the front of the fireplace. If it is not, measure the depth of the hearth. Loosen the
three screws of the leveling “L” bracket at the back of the appliance. Lower it to the
measurement obtained and tighten the screws
APPLIANCE DESCRIPTION
ELECTRICAL CONNECTIONS
The Optima 40-SB comes complete with a temperature activated fan and rheostat installed
and wired to a three-prong (grounding) plug for your protection against shock hazard and
should be plugged in directly into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
NOTE: This appliance, when installed, must be electrically grounded in accordance with local
codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical code, CSA C22.1.
TOP VIEW
On/Off Rocker
Switch
Exhaust
Fresh Air Intake
Gas Inlet side
and power cord
outlet