LEVELING THE OPTIMA 40-SB DIRECT VENT INSERT

Before placing the appliance into the fireplace, check the hearth of the fireplace to see if it is
level with the front of the fireplace. If it is not, measure the depth of the hearth. Loosen the
three screws of the leveling “L” bracket at the back of the appliance. Lower it to the
measurement obtained and tighten the screws

APPLIANCE DESCRIPTION

ELECTRICAL CONNECTIONS

The Optima 40-SB comes complete with a temperature activated fan and rheostat installed
and wired to a three-prong (grounding) plug for your protection against shock hazard and
should be plugged in directly into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.

NOTE: This appliance, when installed, must be electrically grounded in accordance with local
codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical code, CSA C22.1.

TOP VIEW

On/Off Rocker

Switch

Exhaust

Fresh Air Intake

Gas Inlet side

and power cord

outlet