Operation instructions – Archgard 3600-DVTR24N User Manual
Page 31

Optima 3600 –1
31
Set the thermostat, if present, to the lowest level. Set the remote switch to the OFF position.
Set the flame adjustment knob to the HI position. Press slightly and turn the control knob
clockwise
to the OFF position and wait 5 minutes; thus allowing any gases to escape which
may have accumulated in the combustion chamber.
Note: LP gases do not vent upward. Then follow step 2 and 3 to establish pilot.
1.
Press slightly and turn control knob counterclockwise
to PILOT position; depress control
knob and light pilot by repeatedly pressing the sparker. Venting of air may take place at the
pilot prior to the flow of fuel gases. Once flame is established, hold knob depressed in the
PILOT position for approximately 60 sec.
2.
Release knob. If pilot should go out, turn the control knob to OFF position and repeat steps 1,
2 and 3. Note: this will allow reset of INTERLOCK for proper lighting of pilot.
3.
Once the pilot is established, press and turn control knob counterclockwise
to ON position.
4.
6.
Turn flame and fan adjustment knob to the desired comfort level using HI / LOW knob.
To turn off the main burner only, set the thermostat to the lowest setting or turn remote switch to OFF.
Press and turn the knob clockwise
to PILOT position.
Press and turn the knob clockwise
to the OFF position.
5.
Turn thermostat to the desired comfort level or turn the ON/OFF switch to the ON position.
OPERATION INSTRUCTIONS
START-UP PROCEDURE
TEMPORARY SHUT-DOWN PROCEDURE
COMPLETE SHUT-DOWN PROCEDURE